When reviewing a glass bottle test report, the first question is whether the evidence supports the packaging you intend to buy. Read the sample description, assessment scope and intended-use conditions before the conclusion. This workflow helps a sourcing team identify gaps without treating a report as a factory-wide approval.

1. Match the sample to the proposed order

Compare the report number and sample reference with the drawing, photographs, material description, decoration and closure list. Record differences rather than assuming that a matching silhouette proves equivalence. Check whether the laboratory tested a complete assembly, the bare bottle or only one component.

For a product family, ask for the basis of coverage: the named variants, a representative sample or a documented worst-case selection. A different colour or size is a question for scope review, not automatic proof that the report is either valid or invalid.

2. Check the issuer and document integrity

Identify the laboratory, applicant, sample-received date, test dates and complete page count. Ask the issuer to confirm a report through its official contact channel if authenticity is uncertain. A logo or cropped conclusion page is insufficient. Where accreditation is claimed, verify that the relevant method falls within its scope; the presence of an accreditation mark does not make every service accredited.

3. Read methods, conditions and criteria together

For each test, record what was measured, the method version, medium, duration, temperature, units and acceptance criterion. Ask why the exposure represents the proposed contents and use. “Not detected” also needs a reporting limit; it is not the same as proving that no substance exists.

Do not assume the plastic overall migration tests in Regulation (EU) No 10/2011 form a universal glass test list. The assessor should identify the relevant requirements for the glass, coating, closure and liner separately. A sensory result, an elemental release result and a total-content analysis are different evidence types.

Illustration of glass bottle samples beside beakers of differently coloured liquids
Illustrative bottle and liquid comparison. The colours do not identify recognised simulants or demonstrate test results.

4. Use a report review matrix

Report fieldCompare withFollow-up question
Sample identityDrawing and component listWhich parts were submitted?
CoverageVariants and artwork revisionWhat supports family coverage?
ExposureContents, heat and storage briefAre the intended conditions covered?
ResultsUnits, reporting limits and criteriaWhat does each conclusion mean?
ExclusionsUntested components or usesWhat remains to assess?
RevisionCurrent materials and processHave changes been reviewed?

5. Separate the report from the supply file

Keep the report with the approved specification, relevant material information and an order reference. A laboratory normally evaluates the submitted sample; the purchasing team still needs evidence connecting that sample to the supplied goods. Ask the supplier how changes will be notified, who authorises substitutions and which batch or shipment identifiers will be provided.

Agree any required declarations separately. Their legal basis and content depend on the applicable materials and rules. A supplier statement cannot expand the scope of a laboratory report, and a report alone does not establish that every future batch is identical.

Questions buyers ask

Does a report have one universal expiry date?

Do not infer validity from age alone. Check any stated validity, changes to the product or rules, and the importer’s requirements with the assessor.

Can a bare-bottle report cover a decorated order?

Only where the assessment actually supports that coverage. Identify the added decoration materials and contact routes for review.

Must every variant be tested separately?

The scope may support representative testing. Obtain the assessor’s rationale for the variants being ordered instead of making that assumption yourself.

What if the supplier only sends a certificate page?

Request the complete report and its sample identification, methods, results and limitations before approving the evidence.

Food-contact evidence checklist

Plan the sourcing stages

Discuss your bottle requirements

Send your bottle specification, intended contents and destination with the enquiry. Ask which report and sample references are available for that exact proposal, then have their scope reviewed before ordering.

Browse glass packaging

Send a bottle enquiry

Official references

Regulatory references checked on 20 November 2026. The checklists above are practical sourcing guidance; a laboratory or regulatory specialist should confirm the requirements for the proposed finished article.

EU framework: documentation and traceability

European Commission material-specific rules

Facebook